Feature:
1. Automatic running, large LCD screen.
2. Cultivation temperature selection: Room temperature. 25°C,30°C,37°C, 42°C.
3. 38+2 programs can be programmed which is flexible, convenient and long-term preservation.
4. 36 reagent strips can be tested at the same time.
5. Unique design negative pressure suction nozzle. Ensure that the instrument has no cross infection.
6. Automatic cleaning function: each strip can be cleaned as needed.
7. Position function: the arm has the adding/absorbing solution and location check function.
8. Pump can be automatically corrected of the liquid adding error under the control of the computer, and the quantitative correction function of the liquid pump.
9. Safety protection for operators is provided by fully closed piping system.
10. The program can be locked and unlocked.
11. Alarm function: Alarm can be set by adding reagent, substrate, waste liquid overflow and at the end of the test.
12. Setting functions: set up pump name, project locked or unlocked, inquirys, insertion and deletion, etc.
Technical Parameter:
Model |
XD236 |
Test Strip Capacity |
1-36 or 1-30 strip |
Programming Capacity |
≥ 38+2 (fixed procedure) |
Number of Programmable Steps |
20 steps* 6 working phases |
Liquid Dispensation System |
Standard 6-channel pumps liquid dispensing system |
Pump Dispensing Range / Increment |
250μl ~ 3000μl, 1μl increment |
Accuracy of The Pump Dispensing |
±3.0% (dispensing volume 2000μl ) |
Precision of The Pump Dispensing |
CV ≤ 5.0% (dispensing volume 2000μl) |
Quantitative Correction |
Quantitative correction |
Incubation Time / Increment |
0~24 hours / 1 min increment; can be recycled |
Incubation Time Display |
Hours, minutes and seconds |
Shaking Speed |
3 gear optional |
Temperature Control of Shaker |
Accuracy ± 1.5 ℃, Fluctuation ≤ 0.2 ℃ at 37 ℃; Accuracy ± 1.5 ℃, Fluctuation ≤ 0.25 ℃ at 30 ℃ or 25 ℃ |
Display |
Dot matrix LCD with backlight |
Communication |
RS232 Interface, Baud 9600, Data bit 8, stop bit 1, parity check: NO |
Alarming |
Alarms for reagents dispensing, waste overflow, work ending etc. |
Cleaning |
Automatic rinsing when necessary |
Reagent Bottle Capacity |
200ml *5 |
Wash Bottle Capacity |
1000 ml* 1 |
Waste Bottle Capacity |
2000ml*1 (airtight negative-pressure liquid waste bottle) |
Cross Contamination |
When negative and positive samples are tested in turn, the negative samples should not show positive bands |
Working Condition |
Indoor use, altitude ≤ 3000m, 5~40 ℃, RH ≤ 80% at temperature < 31 ℃ |
Power Supply |
110~240V, 50/60Hz, 250VA |
External Size(W*D*H) |
630*500*400mm |
Packed Size(W*D*H) |
840*630*840mm |
Net weight |
33kg |
Gross weight |
70kg |