Introduction:
Features:
Sample Tray:
Disc design, up to 60 samples loading capacity per batch
The position of sample, standard product and quality control positions can be edited
Support emergency function.
Reagent Tray:
Patented semiconductor refrigeration technology
Up to 30 reagent position on board with refrigeration at 2-8℃
Up to 30 items can be tested at the same time.
Washing and mixing module:
Incubation, cleaning and testing one-machine design;
Fully enclosed independent incubation system with 58 incubation positions;
12 independent cleaning positions;
Triple magnetic separation cleaning technology is adopted;
Original photon counting dark chamber.
Sample Probe:
Excellent rinsing system make carry-over ≤10-5
Liquid-level and blood coagulation detection system
Intelligent anti-collision function
Sampling volume: 15ul-100ul
RV Loading Module:
Reaction vessels can be added by pouring, without manual arrangement.
Incubation plate:
80 incubation positions
Constant 37°C incubation
Instrument Software:Flexible sample test mode: STAT function, automatic dilution, reset function, continuous loading
Reagent management: the remaining amount, calibration validity, expiry date management
Consumables management: continuous monitoring and low-level warning
Result management: store search, print and statistics, automatic unit conversion function
LIS/HIS connection
Auto daily maintenance
Models:
|
Model |
BKI1100 |
|
Throughput |
180T/H |
|
Principle |
Magnetic particle enzymatic chemiluminescence |
|
Modes of Operation |
Random, Batch and STAT |
|
Separation method |
Magnetic separation technology |
|
Sample Positions |
60 (Each position could be used as an emergency position) |
|
Reagent Positions |
25 pcs (2-8℃ refrigeration) |
|
Incubation Positions |
58 |
|
Time to 1st Result |
18 Minutes |
|
Sample Volume |
10-200μl |
|
Detection Precision |
CV≤5% |
|
Carry-over Rate |
≤10-5 |
|
Correlation Coefficient |
r≥0.99 |
|
Calibration Stability |
28 Days |
|
Calibration Type |
6/7-point calibration |
|
Software system |
Windows 7/8/10, 32 or 64 bit |
|
Bi-direction, support HL7 protocol |
|
|
Intuitive User Interface, Intelligent Data Management |
|
|
Interface |
TCP/IP Network interface |
|
Other Function |
Liquid level detection |
|
Anti-collision function |
|
|
Sample barcode scanning |
|
|
Reagent radio frequency identification |
|
|
Intelligent alarm prompt |
|
|
Power Supply |
AC110/220V,50/60Hz |
|
External Size (W*D*H) |
768*771*568 |
|
Net Weight |
94Kg |
|
Package Size (WD*H) |
1303*873*854mm |
|
Gross Weight |
163kg |
Reagent Menu:
|
Thyroid |
TSH;TT4;TT3;FT4;FT3;TgAb;TPOAb;TG;Anti-TSHR; CT |
|
Anemia |
FERRITIN;VB12;FA |
|
Liver Fibrosis |
CIV;LN;HA;PIIINP |
|
Hypertension |
ALD;ACTH;Cortisol; Renin |
|
Fertility |
β-HCG;E2;P;T;PRL;FSH; LH;DHEA-S;SHBG;AMH |
|
Growth |
GH |
|
Bone Metabolism |
BGP; 25-OH-Vit-D; iPTH;BGP |
|
Tumor Marker |
CA125;CA15-3;CA199;AFP;CEA; t-PSA; f-PSA |
|
Pepsinogen |
PGI;PGII |
|
Kidney Function |
β2-MG |
|
Rheumatism |
Anti-CCp |
|
Diabetes |
C-P;INS |
|
ardiac Marker |
cTnl; CK-MB;MYO; NT-proBNP |
|
lnflammation |
PCT;IL-β |