Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH |
Measuring function |
|
|
Current measurement AC |
|
|
Measuring range |
Resolution |
Accuracy |
60 A |
0.01 A |
± 2% + 8 Dgt |
600 A |
0.1 A |
± 2% + 8 Dgt |
1000 A |
1 A |
± 2% + 8 Dgt |
|
|
|
Maximum input current: 1000 A AC |
Frequency range: 40 …. 400 Hz |
|
|
|
Measuring function |
|
|
Inrush current AC |
|
|
Measuring range |
Resolution |
Accuracy |
60 A |
0.01 A |
For reference only |
600 A |
0.1 A |
± 5% + 60 Dgt |
1000 A |
1 A |
± 5% + 60 Dgt |
|
|
|
Integral time: 100 ms |
|
Measuring range: 20 … 1000 A |
|
Frequency range: 40 …. 400 Hz |
|
|
|
Measuring function |
|
|
Voltage measurement DC |
|
|
Measuring range |
Resolution |
Accuracy |
6V |
0.001V |
± 0.5% + 5 Dgt |
60V |
0.01V |
± 0.5% + 5 Dgt |
600V |
0.1V |
± 0.5% + 5 Dgt |
1000V |
1V |
± 0.8% + 4 Dgt |
|
|
|
Input impedance: 10 MΩ |
Maximum input voltage: 750V AC (rms value) or 1000V DC |
|
|
|
Measuring function |
|
|
Voltage measurement AC |
|
|
Measuring range |
Resolution |
Accuracy |
6V |
0.001V |
± 0.6% + 4 Dgt |
60V |
0.01V |
± 0.6% + 4 Dgt |
600V |
0.1V |
± 0.6% + 4 Dgt |
1000V |
1V |
± 0.8% + 4 Dgt |
|
|
|
Input impedance: 10 MΩ |
Maximum input voltage: 750V AC (rms value) or 1000V DC |
Frequency range: 40 … 400 Hz |
|
|
|
Measuring function |
|
|
Frequency measurement with |
|
|
The current measuring function |
|
|
Measuring range |
Resolution |
Accuracy |
99.99 Hz |
0.01 Hz |
± 1.5% + 5 Dgt |
999.9 Hz |
0.1 Hz |
± 1.5% + 5 Dgt |
|
|
|
Measuring range: 10 … 1 kHz |
Measuring range of the input signal: > 20 AAC (rms value) |
The input current increases with the measuring frequency. |
Maximum input current: 1000 AAC (rms value) |
|
|
|
Measuring function |
|
|
Frequency measurement with the |
|
|
Voltage measurement function |
|
|
Measuring range |
Resolution |
Accuracy |
99.99 Hz |
0.01 Hz |
± 1.5% + 5 Dgt |
999.9 Hz |
0.1 Hz |
± 1.5% + 5 Dgt |
9,999 kHz |
0.001 kHz |
± 1.5% + 5 Dgt |
|
|
|
Measuring range: 10 … 10 kHz |
Measuring range of the input signal: > 1V AC (rms value) |
The input current increases with the measuring frequency. |
Maximum input voltage: 1000V AC (rms value) |
|
|
|
Measuring function |
|
|
Frequency measurement |
|
|
Measuring range |
Resolution |
Accuracy |
9,999 Hz |
0.001 Hz |
± 0.3% + 5 Dgt |
99.99 Hz |
0.01 Hz |
± 0.3% + 5 Dgt |
9,999 kHz |
0.1 Hz |
± 0.3% + 5 Dgt |
999.9 Hz |
0.001 kHz |
± 0.3% + 5 Dgt |
99.99 kHz |
0.01 kHz |
± 0.3% + 5 Dgt |
999.9 kHz |
0.1 kHz |
± 0.3% + 5 Dgt |
9,999 MHz |
0.001 MHz |
± 0.3% + 5 Dgt |
|
|
|
Overvoltage protection: 1000V DC or 750V AC (rms value) |
Range of voltage input> 2V |
(as the input voltage increases, so does the frequency) |
|
|
|
Measuring function |
|
|
Duty cycle |
|
|
Measuring range |
Resolution |
Accuracy |
0.1 … 99.9% |
0.1% |
± 0.3% + 5 Dgt |
|
|
|
Frequency range: 10 … 10 kHz |
Voltage range: 2 … 250V AC (rms value) |
(The voltage increases with the frequency) |
|
Duty cycle with the |
Frequency range: 10 … 1 kHz |
Current measurement function |
Input current: 20 … 1000 AAC (rms value) |
|
Duty cycle with the |
Frequency range: 10 … 1 kHz |
Voltage measurement function |
Input current: 1 … 750V AC (rms value) |
|
Input impedance: 1MΩ |
|
|
|
Measuring function |
|
|
Resistivity |
|
|
Measuring range |
Resolution |
Accuracy |
600 Ω |
0.1 Ω |
± 0.8% + 3 Dgt |
6 kΩ |
0.001 kΩ |
± 0.8% + 3 Dgt |
60 kΩ |
0.01 kΩ |
± 0.8% + 3 Dgt |
600 kΩ |
0.1 kΩ |
± 0.8% + 3 Dgt |
6 MΩ |
0.001 MΩ |
± 2% + 5 Dgt |
60 MΩ |
0.1 MΩ |
± 2% + 5 Dgt |
|
|
|
Measuring voltage: approx. 0.78V |
Overvoltage protection: 750V DC, 1000V AC (rms value) |
|
|
|
Measuring function |
|
|
Continuity test |
|
|
Measuring range |
Resolution |
Accuracy |
600 Ω |
0.1 Ω |
– |
|
|
|
Acoustic signal at < 50 Ω |
Test voltage: 1.48V |
Overvoltage protection: 750V DC, 1000V AC (rms value) |
|
|
|
Measuring function |
|
|
Capacitance measurement |
|
|
Measuring range |
Resolution |
Accuracy |
9.999 nF |
0.001 nF |
± 3% + 5 Dgt |
99.99 n.f. |
0.01 nF |
± 3% + 5 Dgt |
999.9 nF |
0.1 nF |
± 3% + 5 Dgt |
9.999 μF |
0.001 μF |
± 3% + 5 Dgt |
99.99 μF |
0.01 μF |
± 3% + 5 Dgt |
999.9 μF |
0.1 μF |
± 3% + 5 Dgt |
9,999mF |
0.001 mF |
± 3% + 5 Dgt |
99.99 mF |
0.01 mF |
± 3% + 5 Dgt |
|
|
|
Overvoltage protection: 750V DC, 1000V AC (rms value) |
|
|
|
Measuring function |
|
|
Diode measurement |
|
|
Measuring range |
Resolution |
Accuracy |
3V |
0.001V |
– |
|
|
|
DC anode side: approx. 1-mA |
DC cathode side: approx. 3.2V |
Overvoltage protection: 750V DC, 1000V AC (rms value) |
|
|
|
Measuring function |
|
|
Single phase power measurement |
|
|
Measuring range |
Resolution |
Accuracy |
3 W / VA / Var |
0.01 W / VA / Var |
± 3% + 5 Dgt |
100 W / VA / Var |
0.1 W / VA / Var |
± 3% + 5 Dgt |
4000 W / VA / Var |
1 W / VA / Var |
± 3% + 5 Dgt |
10 kW / VA / var |
0.01 kW / VA / Var |
± 3% + 5 Dgt |
100 kW / VA / var |
0.1 kW / VA / Var |
± 3% + 5 Dgt |
750 kW / VA / var |
1 kW / VA / Var |
± 3% + 5 Dgt |
|
|
|
Smallest measuring current: 1-mA |
Smallest measuring voltage: 1V |
|
|
|
Measuring function |
|
|
Power factor capacitive / inductive |
|
|
Measuring range |
Resolution |
Accuracy |
0.1 … 1 |
0.001 |
± 5% + 5 Dgt |
|
|
|
Smallest measuring current: 1-mA |
Smallest measuring voltage: 1V |
|
|
|
Measuring function |
|
|
Harmonics measurement |
|
|
Measuring range |
Resolution |
Accuracy |
1 |
– |
± 3% + 10 Dgt |
2 … 6 |
– |
± 3.5% + 10 Dgt |
7 … 8 |
– |
± 4.5% + 10 Dgt |
9 … 10 |
– |
± 5% + 10 Dgt |
11 … 15 |
– |
± 7% + 10 Dgt |
16 … 20 |
– |
± 10% + 10 Dgt |
|
|
|
Smallest measuring current: 1-mA |
Smallest measuring voltage: 1V |
The resolution depends on the voltage measuring range |
|
|
|
General specifications |
|
|
Measuring range |
Automatically and manually adjustable |
Maximum voltage range |
1000V DC or 750V AC |
Maximum working height |
2000 m / 6561 ft |
Display |
LCD |
Maximum display |
5999 Dgt. |
Overrange |
“OIL” |
Measuring range underflow |
“-OL” |
Measuring rate |
3 Hz |
Automatic shutdown |
After 30 minutes |
Power supply |
9V block battery |
Battery indicator |
Icon if the battery voltage is too low |
Temperature coefficient |
0.1 x accuracy x °C / °F* |
Operating conditions |
0 … 40°C, 32 … 104°F |
Storage conditions |
-10 … 60°C, 14 … 140°F |
Dimensions |
238 x 92 x 50 mm / 9.4 x 3.6 x 2 in |
Weight |
About 420 g / < 1 lb (with batteries) |
|
|
Accuracies are given at ambient conditions of 18 … 28°C / 65 … 83°F. *The temperature is the difference between the temperature of the operating conditions and the current ambient temperature. |
|
|
Example: |
|
Is the current ambient temperature greater than the temperature of the operating conditions |
(50°C / 122°F (current ambient temperature)) – (40°C / 104°F (operating temperature) = 10°C / 50°F |
Is the current ambient temperature less than the temperature of the operating conditions |
(0°C (operating temperature)) – (-5°C / 23°F (current ambient temperature)) = 5°C / 41°F |
|
Reviews