Cleaning Solution for Skin Grease and Sebum (500 mL)

SKU : 1de94e690833

The HI70621L is a neutral, effective cleaning solution that is specially formulated for use in applications were a pH electrode can be coated with skin grease and sebum. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

  • Specially formulated cleaning solution to remove skin grease and sebum from a pH electrode
  • Air tight bottle with tamper-proof seal to ensure quality
  • Expiration date and lot number clearly marked on the bottle

Info penawaran harga dan pemesanan hubungi:

SKU 1de94e690833 Kategori :

 

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

electrode-cleaning-illustration

The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI70621L is a cleaning solution made specifically for applications that involve the measurement of skin pH, where the electrode can become contaminated from grease or sebum.

 

Air tight bottle with tamper-proof seal

  • Ensures quality and freshness of solution

Each bottle marked with lot number and expiration date

  • Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

 

 

Request penawaran harga & konsultasi produk?

Silakan isi form ini dan kami akan segera membalas ke kontak Anda!

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.