Maintain the long-term stability of the instrument
Automatic calibration
Temperature and humidity operation compensation function
Dual optical path spectral analysis technology
Support SCI + SCE simultaneous rapid measurement
Excellent long-term stability, which can ensure excellent measurement stability even after rapid environmental changes
-
Stable lighting source
It has two kinds of lighting sources: pulse xenon lamp and led
High stability UV light source provides stable fluorescence measurement performance
Technical parameter
Model | CS-821N |
Illumination/ Viewing System
|
Reflectance: d/8(Diffused illumination, 8 degree viewing);Simultaneous measurement of SCI/SCE, conform to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 condition C, ASTM E1164, ASTM-D1003-07 Transmittance d/0(Diffused illumination, 0 degree viewing )
|
Sensor |
Silicon Photodiode Array
|
Grating Method
|
Concave grating |
Sphere diameter | 152mm |
Wavelength range | 360nm-780nm |
Wavelength interval | 10nm |
Half width
|
5nm |
Reflectance Range Resolution
|
0-200%, resolution 0.01% |
Lighting source
|
Pulsed xenon lamp and LED |
UV measurement
|
Including UV, 400nm cut, 420nm cut and 460nm cut |
Measurement time |
SCI/SCE < 2s;SCI+SCE < 4s
|
Measurement / illumination aperture |
Reflection: xlav ΦΦ 30mm ,LAV ΦΦ 18mm MAV Φ 8mm/ Φ 11mm ,SAV Φ 6mm
(Auto aperture size recognition) Aperture for transmission: Φ 25mm
|
Transmittance Sample Size
|
No limit on sample width and height, thickness ≤50mm |
Long term repeatability |
XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 (20℃±10℃ arbitrary temperature
change, white tile is measured every hour within 24 hours)
|
Repeatability※ |
XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1% XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 10-second intervals after white calibration |
Inter-Instrument Agreement
※※ |
XLAV ΔE*ab 0.2 (BCRA Series II, Average measurement of 12 tiles, at 23℃)
|
Observer | 2 ° and 10 ° |
Illuminants
|
A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84 |
Language |
English, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish,Chinese (simple and traditional)
|
Display
|
Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency |
Color space | L*a*b,L*C*h,Hunter Lab,Yxy,XYZ |
Color index |
WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby)
YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness,
color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner,
Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength
|
Colour-difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc,ΔE*94,ΔE*00,ΔEab(Hunter),555 hue classification |
Storage space | 8GB |
Screen size | 7-inch touch screen |
Operating system | Android |
Power Supply |
DC stabilized power supply
|
Operating temperature and humidity range | 5 ~ 40 ° C, relative humidity below 80% (at 35 ° C), no condensation |
Storage temperature and humidity range | -20 ~ 45 ° C, relative humidity below 80% (at 35 ° C), no condensation |
Accessories
|
Power adapter, data cable, transmission fixture, software USB flash disk, black cavity, white board, green board, 0% calibration shading cover (820n attached), 30mm diameter board,18mm diameter board, 11mm diameter board, 6mm diameter board,support table, cuvette, damping handle
|
Optional Accessories |
Heating transmission fixture (including control circuit), vertical support, pneumatic ejector rod(including control circuit), small sample clamping accessories, pull rod box,European standard plug and American standard plug Reflective cuvette support, corrosion-resistant protective plate (non removable), fiber test box, film clamp and micro transmission clamp
|
Interface | RS-232ã€USBã€USB-B |
Other function |
1. Camera viewfinder positioning;
|
※After the instrument is calibrated, measure the white correction plate 30 times at an interval of 5 seconds, and measure the standard deviation of the results with xlav caliber
※※ Based on the average of xlav caliber measurements of 12 color plates of BCRA series at 23 ° C
Jika Anda tertarik untuk memperoleh Alat Ukur Intensitas Cahaya atau peralatan uji dan ukur lainnya, maka Alat-Test adalah mitra yang dapat Anda percayai! Kami menyediakan berbagai alat laboratorium dan uji untuk berbagai industri. Produk berkualitas tinggi kami telah membantu banyak perusahaan meningkatkan kontrol kualitas dan efisiensi produksi mereka.
Kami memiliki berbagai jenis Alat Ukur Intensitas Cahaya dan peralatan uji lainnya yang dapat disesuaikan dengan kebutuhan Anda. Kami siap memberikan informasi lebih lanjut dan membantu Anda memilih peralatan yang paling cocok untuk bisnis Anda.
Hubungi Kami Sekarang!
Jangan ragu untuk menghubungi kami melalui salah satu cara berikut:
- Telepon: 02816572222
- Email: contact@alat-test.com
- Whatsapp: 085717112222
- Kontak Form: Klik di sini
Tim kami siap memberikan informasi lebih lanjut, memberikan penawaran khusus, dan membantu Anda menemukan solusi yang tepat untuk kebutuhan uji dan ukur Anda.</p
Jadi, jangan ragu untuk menghubungi Alat-Test sekarang juga! Kami adalah mitra yang handal untuk kebutuhan peralatan uji dan ukur Anda. Dengan bantuan kami, Anda dapat meningkatkan kualitas produk Anda dan mencapai keberhasilan yang lebih besar dalam bisnis Anda. Terima kasih telah membaca, dan kami berharap dapat bekerja sama dengan Anda segera! ️