DURAC® Plus™ ASTM Like Liquid-In-Glass Thermometer

SKU : 78ddf685d596

Info penawaran harga dan pemesanan hubungi:

SKU 78ddf685d596 Kategori :

Mercury Free, these ASTM Like thermometers are safer to use than their mercury counterparts.

  • Ideal for use in quality control laboratories or when mercury filled thermometers cannot be used, but ASTM standards are still needed
  • Feature blue organic liquid fill against lead-free white back glass

Note: The following DURAC® Plus™ thermometers include an individualized Thermometer Calibration Report stating corrections to one-tenth of the smallest division, unique report number and NIST standards used for the calibration:

  • 1212N98 (B60750-3500) at 20, 32, 50, 70, 88°F

 

 RangeDiv.AccuracyImmersionASTMLength
1212N61-20/150°C1°C±1°C; ±1.5°C above 100°CPartial: 76mm1C / Partial Immersion322mm (12.7”)
1212N620/302°F2°F±2°F; ±3°F above 212°FPartial: 76mm1F / Partial Immersion322mm (12.7”)
1212N63-38/50°C1°C±1°CPartial: 108mm5C / Cloud and Pour231mm (9.1”)
1212N64-36/120°F2°F±2°FPartial: 108mm5F / Cloud and Pour231mm (9.1”)
1212N65-80/20°C1°C±1°C; ±2°C below -33°CPartial: 76mm6C / Low Cloud and Pour232mm (9.1”)
1212N66-112/70°F2°F±2°F; ±4°F below -28°FPartial: 76mm6F / Low Cloud and Pour232mm (9.1”)
1212N67-5/110°C0.5°C±1°CPartial: 57mm9C / Low-Pensky-Martens287mm (11.3”)
1212N6820/230°F1°F±2°FPartial: 57mm9F / Low-Pensky-Martens287mm (11.3”)
1212N69-20/102°C0.2°C±0.6°CTotal12C / Density-Wide Range420mm (16.5”
1212N70-5/215°F0.5°F±0.25°FTotal12F / Density-Wide Range420mm (16.5”)
1212N7138/82°C0.1°C±0.4°CPartial: 79mm14C / Wax Melting?Point377mm (14.8”)
1212N72100/180°F0.2°F±0.6°FPartial: 79mm14F / Wax Melting Point377mm (14.8”)
1212N73-2/80°C0.2°C±0.4°CTotal15C / Low Softening Point397mm (15.6”)
1212N7430/180°F0.5°F±1°FTotal15F / Low Softening Point397mm (15.6”)
1212N7530/200°C0.5°C±1°C; ±1.5°C above 120°CTotal16C / High Softening Point397mm (15.6”)
1212N7685/392°F1°F±1°F; ±2°F above 220°FTotal16F / High Softening Point397mm (15.6”)
1212N7719/27°C0.1°C±0.2°CTotal17C / Saybolt Viscosity275mm (10.8”)
1212N7866/80°F0.2°F±0.6°FTotal17F / Saybolt Viscosity275mm (10.8”)
1212N7934/42°C0.1°C±0.3°CTotal18C / Reid Vapor Pressure275mm (10.8”)
1212N8094/108°F0.2°F±0.6°FTotal18F / Reid Vapor Pressure275mm (10.8”)
1183K02120/134°F0.2°F±0.6°FTotal19F / Saybolt Viscosity280mm (11”)
1212N81-38/42°C0.2°C±0.6°CPartial: 50mm33C / Low Aniline Point419mm (16.5”)
1212N82-36.5/107.5°F0.5°F±1°FPartial: 50mm33F / Low Aniline Point419mm (16.5”)
1212N83-2/68°C0.2°C±0.6°CPartial: 45mm36C / Titer Test405mm (16”) 
1212N84-2/52°C0.2°C±0.6°CPartial: 100mm37C / Solvents Distillation395mm (15.5”)
1212N8524/78°C0.2°C±0.6°CPartial: 100mm38C / Solvents Distillation395mm (15.5”)
1212N8648/102°C0.2°C±0.6°CPartial: 100mm39C / Solvents Distillation395mm (15.5”)
1212N8772/126°C0.2°C±0.6°CPartial: 100mm40C / Solvents Distillation395mm (15.5”)
1212N8820/70°C0.2°C±0.6°CPartial: 65mm49C / Stormer Viscosity305mm (12”)
1212N89-10/5°C0.1°C±0.3°CTotal52C / Butadiene Boiling Point Range162mm (6.4”)
1212N9020/100.6°C0.2°C±0.6°CTotal54C / Congealing Point312mm (12.3”
1212N9168/213°F0.5°F±1°FTotal54F / Congealing Point312mm (12.3”
1212N92-20/50°C0.5°C±1°CPartial: 57mm57C / Tag Closed Tester, Low Range287mm (11.3”)
1212N93-4/122°F1°F±2°FPartial: 57mm57F / Tag Closed Tester, Low Range287mm (11.3”)
1212N94-34/49°C0.5°C±0.6°CTotal58C / Tank303mm (11.9”)
1212N9818/89°F0.2°F±0.6°FTotal63F / Precision General Purpose379mm (14.9”)
1212N99-15/105°C1°C±1°CPartial: 30mm82C / Fuel Rating, Engine162mm (6.4”)
1212P000/220°F2°F±2°FPartial: 30mm82F / Fuel Rating, Engine162mm (6.4”)
1212P0115/70°C1°C±1°CPartial: 40mm83C / Fuel Rating, Air Low171mm (6.7”)
1212P0260/160°F1°F±2°FPartial: 40mm83F / Fuel Rating, Air Low171mm (6.7”)
1212P0325/80°C1°C±2°CPartial: 249mm84C / Fuel Rating Orifice Tank382mm (15”)
1173H0275/175°F1°F±4°FPartial: 249mm84F / Fuel Rating Orifice Tank382mm (15”)
1212P0440/150°C1°C±1°C; ±1.5°C above 100°CPartial: 181mm85C / Fuel Rating, Surge310mm (12.2”)
1212P05100/300°F2°F±2°F; ±3°F above 200°FPartial: 181mm85F / Fuel Rating, Surge310mm (12.2”)
1212P0695/175°C1°C±1.5°CPartial: 35mm86C / Fuel Rating, Mix167mm (6.6”)
1212P07200/350°F2°F±3°FPartial: 35mm86F / Fuel Rating, Mix167mm (6.6”)
1212P0810/200°C1°C±1°C; ±1.5°C above 100°CPartial: 57mm88C / Vegetable Oil, Flash287mm (11.3”)
1212P0950/392°F2°F±2°F; ±3°F above 200°FPartial: 57mm88F / Vegetable Oil, Flash287mm (11.3”)
1212P10-20/10°C0.1°C±1°CPartial: 76mm89C / Solidification Point370mm (14.6”)
1212P110/30°C0.1°C±0.3°CPartial: 76mm90C / Solidification Point370mm (14.6”)
1212P1220/50°C0.1°C±0.3°CPartial: 76mm91C / Solidification Point370mm (14.6”)
1212P13-18/49°C0.5°C±0.5°CTotal97C / Tank303mm (11.9”)
1212P140/120°F1°F±0.5°FTotal97F / Tank303mm (11.9”)
1212P15-50/5°C0.2°C±0.4°C; ±0.6°C below -20°CPartial: 35mm99C / Weathering Test302mm (11.9”)
1212P16-55/40°F0.5°F±0.5°F; ±1°F below -10°FPartial: 35mm99F / Weathering Test302mm (11.9”)
1212P17-1/175°C0.5°C±0.5°C; ±1°C above 100°CTotal113C / Softening Point, (Bitumen) Wide Range406mm (16”)
1212P180/350°F1°F±1°F; ±2°F above 200°FTotal113F / Softening Point, (Bitumen) Wide Range406mm (16”)
1212P19-80/20°C0.5°C±1°C; ±1.5°C below -20°CTotal114C / Aviation Fuel Freezing Point300mm (11.8”)
1212P20-112/68°F1°F±2°F; ±3°F below -4°FTotal114F / Aviation Fuel Freezing Point300mm (11.8”)
1183K0323.9/30.1°C0.01°C±0.1°CTotal117C / Bomb Calorimeter300mm (11.8”)
1212P21-7/105°C0.5°C±0.5°CTotal130C / Tank300mm (11.8”)
1212P2220/220°F1°F±1°FTotal130F / Tank300mm (11.8”)

 

Thomas NoMfr NoDescription
1212N61B60750-0000ASTM No. / ASTM Method: 1C / Partial Immersion; Range: -20/150°C
1212N62B60750-0100ASTM No. / ASTM Method: 1F / Partial Immersion; Range: 0/302°F
1212N63B60750-0200ASTM No. / ASTM Method: 5C / Cloud and Pour; Range: -38/50°C
1212N64B60750-0300ASTM No. / ASTM Method: 5F / Cloud and Pour; Range: -36/120°F
1212N65B60750-6400ASTM No. / ASTM Method: 6C / Low Cloud and Pour; Range: -80/20°C
1212N66B60750-6500ASTM No. / ASTM Method: 6F / Low Cloud and Pour; Range: -112/70°F
1212N67B60750-0400ASTM No. / ASTM Method: 9C / Low-Pensky-Martens; Range: -5/110°C
1212N68B60750-0500ASTM No. / ASTM Method: 9F / Low-Pensky-Martens; Range: 20/230°F
1212N69B60750-0600ASTM No. / ASTM Method: 12C / Density-Wide Range; Range: -20/102°C
1212N70B60750-0700ASTM No. / ASTM Method: 12F / Density-Wide Range; Range: -5/215°F
1212N71B60750-0800ASTM No. / ASTM Method: 14C / Wax Melting?Point; Range: 38/82°C
1212N72B60750-0900ASTM No. / ASTM Method: 14F / Wax Melting Point; Range: 100/180°F
1212N73B60750-1000ASTM No. / ASTM Method: 15C / Low Softening Point; Range: -2/80°C
1212N74B60750-1100ASTM No. / ASTM Method: 15F / Low Softening Point; Range: 30/180°F
1212N75B60750-1200ASTM No. / ASTM Method: 16C / High Softening Point; Range: 30/200°C
1212N76B60750-1300ASTM No. / ASTM Method: 16F / High Softening Point; Range: 85/392°F
1212N77B60750-1400ASTM No. / ASTM Method: 17C / Saybolt Viscosity; Range: 19/27°C
1212N78B60750-1500ASTM No. / ASTM Method: 17F / Saybolt Viscosity; Range: 66/80°F
1212N79B60750-1600ASTM No. / ASTM Method: 18C / Reid Vapor Pressure; Range: 34/42°C
1212N80B60750-1700ASTM No. / ASTM Method: 18F / Reid Vapor Pressure; Range: 94/108°F
1183K02B60750-7000ASTM No. / ASTM Method: 19F / Saybolt Viscosity; Range: 120/134°F
1212N81B60750-1800ASTM No. / ASTM Method: 33C / Low Aniline Point; Range: -38/42°C
1212N82B60750-1900ASTM No. / ASTM Method: 33F / Low Aniline Point; Range: -36.5/107.5°F
1212N83B60750-2000ASTM No. / ASTM Method: 36C / Titer Test; Range: -2/68°C
1212N84B60750-2100ASTM No. / ASTM Method: 37C / Solvents Distillation; Range: -2/52°C
1212N85B60750-2200ASTM No. / ASTM Method: 38C / Solvents Distillation; Range: 24/78°C
1212N86B60750-2300ASTM No. / ASTM Method: 39C / Solvents Distillation; Range: 48/102°C
1212N87B60750-2400ASTM No. / ASTM Method: 40C / Solvents Distillation; Range: 72/126°C
1212N88B60750-2500ASTM No. / ASTM Method: 49C / Stormer Viscosity; Range: 20/70°C
1212N90B60750-2700ASTM No. / ASTM Method: 54C / Congealing Point; Range: 20/100.6°C
1212N91B60750-2800ASTM No. / ASTM Method: 54F / Congealing Point; Range: 68/213°F
1212N92B60750-2900ASTM No. / ASTM Method: 57C / Tag Closed Tester, Low Range; Range: -20/50°C
1212N93B60750-3000ASTM No. / ASTM Method: 57F / Tag Closed Tester, Low Range; Range: -4/122°F
1212N94B60750-3100ASTM No. / ASTM Method: 58C / Tank; Range: -34/49°C
1212N99B60750-3900ASTM No. / ASTM Method: 82C / Fuel Rating, Engine; Range: -15/105°C
1212P00B60750-4000ASTM No. / ASTM Method: 82F / Fuel Rating, Engine; Range: 0/220°F
1212P01B60750-4100ASTM No. / ASTM Method: 83C / Fuel Rating, Air Low; Range: 15/70°C
1212P02B60750-4200ASTM No. / ASTM Method: 83F / Fuel Rating, Air Low; Range: 60/160°F
1173H02B60750-4400ASTM Like Liquid-In-Glass Thermometer, 84F / Fuel Rating Orifice Tank, 249mm Immersion, 75 to 175°F, Organic Liquid Fill
1212P04B60750-4500ASTM No. / ASTM Method: 85C / Fuel Rating, Surge; Range: 40/150°C
1212P07B60750-4800ASTM No. / ASTM Method: 86F / Fuel Rating, Mix; Range: 200/350°F
1212P08B60750-4900ASTM No. / ASTM Method: 88C / Vegetable Oil, Flash; Range: 10/200°C
1212P09B60750-5000ASTM No. / ASTM Method: 88F / Vegetable Oil, Flash; Range: 50/392°F
1212P10B60750-5100ASTM No. / ASTM Method: 89C / Solidification Point; Range: -20/10°C
1212P11B60750-5200ASTM No. / ASTM Method: 90C / Solidification Point; Range: 0/30°C
1212P12B60750-5300ASTM No. / ASTM Method: 91C / Solidification Point; Range: 20/50°C
1212P13B60750-5400ASTM No. / ASTM Method: 97C / Tank; Range: -18/49°C
1212P14B60750-5500ASTM No. / ASTM Method: 97F / Tank; Range: 0/120°F
1212P15B60750-5600ASTM No. / ASTM Method: 99C / Weathering Test; Range: -50/5°C
1212P16B60750-5700ASTM No. / ASTM Method: 99F / Weathering Test; Range: -55/40°F
1212P17B60750-5800ASTM No. / ASTM Method: 113C / Softening Point, (Bitumen) Wide Range; Range: -1/175°C
1212P18B60750-5900ASTM No. / ASTM Method: 113F / Softening Point, (Bitumen) Wide Range; Range: 0/350°F
1212P19B60750-6000ASTM No. / ASTM Method: 114C / Aviation Fuel Freezing Point; Range: -80/20°C
1212P20B60750-6100ASTM No. / ASTM Method: 114F / Aviation Fuel Freezing Point; Range: -112/68°F
1183K03B60750-6600ASTM No. / ASTM Method: 117C / Bomb Calorimeter; Range: 23.9/30.1°C
1212P21B60750-6200ASTM No. / ASTM Method: 130C / Tank; Range: -7/105°C
1212P22B60750-6300ASTM No. / ASTM Method: 130F / Tank; Range: 20/220°F

Request penawaran harga & konsultasi produk?

Silakan isi form ini dan kami akan segera membalas ke kontak Anda!

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.