EC Analog Controller with Input from Probe or Transmitter

In Stock : 1
SKU: ac42e4cf0b59 Kategori :

HI8931 series are panel mounted conductivity meters and controllers designed for simplicity of use in a wide range of industrial process applications.

  • Available in four models with different measurement ranges.
  • Temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Backlit, LCD display for easy viewing.

Info penawaran harga dan pemesanan hubungi:

Measurement Specific Models

Four different models are available with different measurement ranges, each one to be used with the corresponding HI 8936 model.

In-line and Tank Use

For in-line applications, use the HI7635 probe, while for tanks the HI7638 with external threads is recommended. These probes are provided with a built-in NTC sensor for temperature compensated conductivity measurements.

Automatic Temperature Compensation

Built-in temperature sensor in recommended probes ensure fast, accurately compensated readings even during sudden temperature fluctuations.

Use With Transmitter

Using the HI8931 in conjunction with a 4-20 mA output transmitter (HI8936 or HI8936L series) will assure a strong, interference free signal at distances up to 300 meters (1000’).

Direct Connection

HI8931 also features a direct connection up to 20 m (67’), without needing to amplify the signal to the conductivity probe.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

 

 

 

Specification Name Detail
sku HI8931
EC Range HI8931AN: 0.0 to 199.9 mS/cm
HI8931BN: 0.00 to 19.99 mS/cm
HI8931CN: 0 to 1999 µS/cm
HI8931DN: 0.0 to 199.9 µS/cm
EC Resolution HI8931AN: 0.1 mS/cm
HI8931BN: 0.01 mS/cm
HI8931CN: 1 µS/cm
HI8931DN: 0.1 µS/cm
EC Accuracy (@20°C/68°F) ±2% F.S. (excluding probe error)
Typical EMC Deviation ±2.5% of Full Scale
±0.4 mA
Temperature Compensation automatic, 0 to 60°C (32 to 140°F), with ?=2%/°C
Calibration manual, two point, through offset and slope trimmers
Recorder Output 4 to 20 mA (isolated)
Setpoint Relay Isolated, 2A, Max. 240V, resistive
Probe HI7635 for in-line applications or HI7638 for tank (not included)
Power Supply 115 or 230 Vac ±10% (user selectable); 50/60 Hz
Alarm Relay load, 1,000,000 strokes
Environment -10 to 50°C (14 to 122°F); RH 95%
Enclosure/ Case Material DIN 43 700, 144×72 mm (5.7×2.8″), black anodized aluminum; front and back with shockproof ABS plastic, and transparent cover
Dimensions 141 x 69 mm (5.6 x 2.7″)
Weight 1 kg (2.2 lb.)

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.