Glass Body Calomel Reference Electrode for Samples with Suspended Solids

The HI5413 is a glass body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a PTFE sleeve junction in the outer reference cell, calomel references, and is made for use in temperatures ranging from -5 to 60°C. This design consideration is made for measurements in samples with suspended solids, and can be used in a variety of titrations.

  • Half-Cell Design
  • Calomel References
  • PTFE Sleeve Junction

Info penawaran harga dan pemesanan hubungi:

SKU 1344479c34c3 Kategori :

 

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI5413 uses a glass body, calomel references, PTFE sleeve junction and is refillable with 3.5M KCl.

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature-dependent. The faster the equilibrium the steadier the reference potential.

PTFE Sleeve Junction

Conventional pH electrodes use ceramic junctions that clog quickly when used in samples with high amounts of particulates. When the junction is clogged, the electrode does not function. The use of a polytetrafluoroethylene (PTFE) sleeve junction prevents clogging of the junction and allows the proper flow of the liquid electrolyte. As a result, pH electrodes with sleeve junctions stay fresh up to 20 times longer than conventional electrodes.

Refillable

The HI5413 is a refillable reference electrode. Since it is a single junction calomel electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single-junction silver/silver chloride reference electrodes. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings. 

4 mm Connector

The HI5413 uses a 4 mm banana connector. This type of connector is easily plugged into the reference input on suitable meters. Other types of connectors include BNC, DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

pH Half Cell and Reference Half Cell

 

 

Specification NameDetail
SKUHI5413
Descriptionreference electrode
Referencesingle, Hg/Hg2Cl2
Junction / Flow Ratee PE sleeve
Electrolytee KCl 3.5M
Max Pressure0.1 bar
Recommended Operating Temperature-5 to 60°C(23 to 140°F)
Body Materialglass
Cable1 m (3.3’)
Recommended Usesamples with suspended solids
Connection4 mm banana

Request penawaran harga & konsultasi produk?

Silakan isi form ini dan kami akan segera membalas ke kontak Anda!

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.