The HI5521 is an advanced research grade benchtop pH/ORP and EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity.
The HI5521 is a two-channel meter that allows for simultaneous measure of pH or ORP on one channel and EC or related parameters on the other. Channel 1 has a BNC connection for use with the expansive line of pH and ORP electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide temperature range from 0 to 100 °C. All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe or from the built in temperature sensor of the conductivity probe on Channel 2. The HI5521 is supplied with the HI76312 four-ring conductivity probe that operates over a wide range from 0.000 ?S/cm to 1000.0 mS/cm*. The meter can be set to auto-ranging in which the meter chooses the appropriate conductivity range from seven ranges or fixed range in which the meter will only display reading in ?S/cm or mS/cm. All readings are automatically compensated for temperature variations with a built in temperature sensor. The temperature correction coefficient is adjustable from 0.00 to 10.00 %/°C.
As a pH meter the HI5521 can be calibrated up to five points with a choice of eight pre-programmed buffers or five custom buffers. The HI5521 features Hanna’s exclusive CAL Check™ to alert the user of potential problems during the pH calibration process. Indicators displayed during calibration include “Electrode Dirty/Broken” and “Buffer Contaminated.” The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete. The calibration data including date, time, buffers used, offset and slope can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.
As an EC/TDS/Salinity/Resistivity meter the HI5521 can be calibrated up to four points with a choice of six pre-programmed conductivity standards or user defined custom standards. Resistivity, TDS, Practical Salinity (PSU) and Natural Seawater Scale are calibrated through conductivity. The % NaCl is calibrated to single point with the HI7037 salinity standard. The calibration data including date, time, and standards used, offset and cell factor can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.
For the measurement of high purity water used in pharmaceutical manufacturing, the HI5521 is programmed with the three stages of the USP <645> method. Once a stage is met a report is generated and can be saved. Up to 200 reports can be stored and with the USB port be transferred to a Windows® compatible computer.
Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points can be recorded in 100 lots with 50,000 records max/lot on each channel and exported to a computer for data review and storage.
Specification Name | Detail |
---|---|
SKU | HI5521-01 |
pH Range | pH: -2.000 to 20.000 |
pH Resolution | pH: 0.1, 0.01, 0.001 |
pH Accuracy (@25°C/77°F) | ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD |
pH Calibration | automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers |
pH Temperature Compensation | automatic or manual from -20.0 to 120.0 °C |
EC Range | 0.000 to 9.999 ?S/cm, 10.00 to 99.99 ?S/cm, 100.0 to 999.9 ?S/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC* |
EC Resolution | 0.001 ?S/cm, 0.01 ?S/cm, 0.1 ?S/cm, 1 ?S/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm |
EC Accuracy | ±1% of reading (±0.01 ?S/cm) |
EC Calibration | automatic standard recognition (0.000 ?S/cm, 84.00 ?S/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration |
TDS Range | 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor) |
TDS Resolution | 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt |
TDS Accuracy | ±1% of reading (±0.01 ppm) |
EC/TDS Temperature Compensation | disabled, linear and non-linear (natural water) |
Temperature Correction Coefficient | 0.00 to 10.00 %/°C |
Resistivity Range | 1.0 to 99.9 ?•cm; 100 to 999 ?•cm; 1.00 to 9.99 K?•cm; 10.0 to 99.9 K?•cm; 100 to 999 K?•cm; 1.00 to 9.99 M?•cm; 10.0 to 100.0 M?•cm |
Resistivity Resolution | 0.1 ?•cm; 1 ?•cm; 0.01 K?•cm; 0.1 K?•cm; 1 K?•cm; 0.01 M?•cm; 0.1 M?•cm* |
Resistivity Accuracy | ±2% of reading (±1 ?•cm) |
Salinity Range | practical scale: 0.00 to 42.00 psu; natural seawater scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0% |
Salinity Resolution | 0.01 for practical scale/natural seawater scale; 0.1% for percent scale |
Salinity Accuracy | ±1% of reading |
Salinity Calibration | percent scale—one-point (with HI7037 standard) |
Salinity Temperature Compensation | disabled, linear and non-linear (natural water) |
Temperature Range | -20.0 to 120.0?C**; -4.0 to 248.0 ?F**; 253.15 to 393.15 K** |
Temperature Resolution | 0.1 °C, 0.1 °F, 0.1 K |
Temperature Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K (without probe) |
pH Electrode | HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included); HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3’) cable (included) |
EC/TDS Probe | HI76312 conductivity probe |
Temperature Probe | HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) |
Power Supply | 12 VDC adapter (included) |
Environment | 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing |
Dimensions | 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) |
Weight | 1.2 kg (2.64 lbs.) |
Ordering Information | HI5521 is supplied with HI1131 pH electrode, HI7662-T temperature probe, HI76312 conductivity probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC power adapter and instructions. |
Method | USP <645> Compliant |
Special Notes | *Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. **Reduced to actual probe limits |
Warranty | 2 years |