Nickel Low Range Portable Photometer

SKU : ce2280006c19

Just a heads up! This Hanna Instruments product is no longer available. Don’t worry though, we’re still here to support you.

Quick question or technical issues? We can help.
Our Tech Team is just a phone call or email away. Please call us at800-426-6287or email us attech@hannainst.comdirectly for assistance. Our hours of operation are8:30am – 5:00pm EST.

Looking for a similar product?Check out our newestversionhere!

The HI96740 Nickel Low Range Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the concentration of nickel within a 0.000 to 1.000 mg/L (ppm) range using the HI93740-0 ready made reagents. The HI96740 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter.

  • CAL Check™ Validation and Calibration
  • Built-in Timer
  • Automatic Shut Off

*Products classified as Dangerous Goods can only be shipped via ground.

Info penawaran harga dan pemesanan hubungi:

SKU ce2280006c19 Kategori :
The HI96740 portable photometer is for the low range measurement of nickel. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Check™ – Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.

GLP – Records the date of the last user calibration performed.

Built in timer – Ensures the appropriate reaction time is used for the chemical reaction. At the end of the timer the meter will automatically take the reading. This feature ensures consistency across multiple users.

Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.

Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.

Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.

Battery status indicator

The instrument has a battery level indicator to display remaining life as follows:

  • 3 lines for 100 % capacity
  • 2 lines for 66 % capacity
  • 1 line for 33 % capacity
  • Battery icon blinks when the capacity is less than 10 %.

Units of measure – Appropriate unit of measure is displayed along with reading.

principal-light

Nickel is commonly utilized by the electroplating industry in processes utilizing stainless steel, cobalt, or nickel alloys. By using nickel in certain alloys, manufacturers can achieve a product that is highly resistant to chemical stress and exhibits a longer lifespan. Nickel is also an essential trace element that is essential for biological processes in livestock health and production. Nickel is also used in batteries, fuel cells, and hydrogenation of vegetable oils in the food industry.

The HI96740 uses an adaptation of the 1-(2-pyridylazo)-2-naphtol PAN method to measure nickel concentrations of less than 1.000 mg/L (ppm). When the reagent is added to samples containing small amounts of nickel, the sample will turn an orange hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For nickel determination, a narrow band interference filter at 575 nm (yellow) allows only yellow light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

Cal-Chck-yellow-1

CAL Check™ standards with certificate

The HI96740-11 CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ function.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage

HI96-series-steps-2

 

 

 

Specification Name Detail
sku HI96740
Nickel, LR Range 0.000 to 1.000 mg/L (ppm)
Nickel, LR Resolution 0.001 mg/L (ppm)
Nickel, LR Accuracy ±0.010 mg/L ±7% of reading
Nickel, LR Method adaptation of the 1-(2-pyridylazo)-2-naphtol PAN method
Light Source tungsten lamp
Light Detector silicon photocell
Power Supply 9V battery
Auto-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Weight 320g (11.3 oz.)
Warranty 2 years