OPTIMA® 17 Capillary Columns

SKU: ac715fcf9aae Kategori :

Info penawaran harga dan pemesanan hubungi:

OPTIMA® 17

Capillary columns for GC

Features

  • Phenylmethylpolysiloxane (50 % phenyl) · USP G3
  • Medium polar phase

Recommended application: steroids, pesticides, drug analyses

Low bleed columns with equal selectivity see OPTIMA® 17 MS

Similar phases: OV-17, DB-17, HP-50+, HP-17, SPB-50, SP-2250, Rtx-50, Rxi-17, CP-Sil 24 CB, 007-17, ZB-50

Max. temperature for isothermal operation 320 °C,

Max. temperature for short isotherms in a temperature program 340 °C

0.53 mm ID columns: max. temperatures 300 and 320 °C, resp.

Thomas NoMfr NoDescription
1151G78726848.10OPTIMA® 17 capillary columns for GC, film thickness: 0.1 µm, length: 10 m, 0.10mm ID, USP: G3
1151C22726065.12OPTIMA® 17 capillary columns for GC, film thickness: 0.2 µm, length: 12 m, 0.2mm ID, USP: G3
1151C23726065.25OPTIMA® 17 capillary columns for GC, film thickness: 0.2 µm, length: 25 m, 0.2mm ID, USP: G3
1151C24726065.50OPTIMA® 17 capillary columns for GC, film thickness: 0.2 µm, length: 50 m, 0.2mm ID, USP: G3
1151C25726066.25OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 25 m, 0.2mm ID, USP: G3
1151C26726066.50OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 50 m, 0.2mm ID, USP: G3
1151G02726742.25OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 25 m, 0.25mm ID, USP: G3
1151G03726742.30OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 30 m, 0.25mm ID, USP: G3
1151G04726742.50OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 50 m, 0.25mm ID, USP: G3
1151G05726742.60OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 60 m, 0.25mm ID, USP: G3
1151B89726022.15OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 15 m, 0.25mm ID, USP: G3
1151B90726022.25OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 25 m, 0.25mm ID, USP: G3
1151B91726022.30OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 30 m, 0.25mm ID, USP: G3
1151B92726022.50OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 50 m, 0.25mm ID, USP: G3
1151B93726022.60OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 60 m, 0.25mm ID, USP: G3
1151C27726067.25OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 25 m, 0.25mm ID, USP: G3
1151C28726067.30OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 30 m, 0.25mm ID, USP: G3
1151C29726067.50OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 50 m, 0.25mm ID, USP: G3
1151C30726067.60OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 60 m, 0.25mm ID, USP: G3
1151G14726755.30OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 30 m, 0.32mm ID, USP: G3
1151D89726351.25OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 25 m, 0.32mm ID, USP: G3
1151D90726351.30OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 30 m, 0.32mm ID, USP: G3
1151D91726351.50OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 50 m, 0.32mm ID, USP: G3
1151D92726351.60OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 60 m, 0.32mm ID, USP: G3
1151G15726757.25OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 25 m, 0.32mm ID, USP: G3
1151G16726757.30OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 30 m, 0.32mm ID, USP: G3
1151G17726757.50OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 50 m, 0.32mm ID, USP: G3
1151G18726757.60OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 60 m, 0.32mm ID, USP: G3
1151G06726744.25OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 25 m, 0.32mm ID, USP: G3
1151G07726744.30OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 30 m, 0.32mm ID, USP: G3
1151G08726744.50OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 50 m, 0.32mm ID, USP: G3
1151G09726744.60OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 60 m, 0.32mm ID, USP: G3
1151G10726747.10OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 10 m, 0.53mm ID, USP: G3
1151G11726747.15OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 15 m, 0.53mm ID, USP: G3
1151G12726747.25OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 25 m, 0.53mm ID, USP: G3
1151G13726747.30OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 30 m, 0.53mm ID, USP: G3

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.