OPTIMA® 17 Capillary Columns

Info penawaran harga dan pemesanan hubungi:

SKU ac715fcf9aae Kategori :

OPTIMA® 17

Capillary columns for GC

Features

  • Phenylmethylpolysiloxane (50 % phenyl) · USP G3
  • Medium polar phase

Recommended application: steroids, pesticides, drug analyses

Low bleed columns with equal selectivity see OPTIMA® 17 MS

Similar phases: OV-17, DB-17, HP-50+, HP-17, SPB-50, SP-2250, Rtx-50, Rxi-17, CP-Sil 24 CB, 007-17, ZB-50

Max. temperature for isothermal operation 320 °C,

Max. temperature for short isotherms in a temperature program 340 °C

0.53 mm ID columns: max. temperatures 300 and 320 °C, resp.

Thomas NoMfr NoDescription
1151G78726848.10OPTIMA® 17 capillary columns for GC, film thickness: 0.1 µm, length: 10 m, 0.10mm ID, USP: G3
1151C22726065.12OPTIMA® 17 capillary columns for GC, film thickness: 0.2 µm, length: 12 m, 0.2mm ID, USP: G3
1151C23726065.25OPTIMA® 17 capillary columns for GC, film thickness: 0.2 µm, length: 25 m, 0.2mm ID, USP: G3
1151C24726065.50OPTIMA® 17 capillary columns for GC, film thickness: 0.2 µm, length: 50 m, 0.2mm ID, USP: G3
1151C25726066.25OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 25 m, 0.2mm ID, USP: G3
1151C26726066.50OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 50 m, 0.2mm ID, USP: G3
1151G02726742.25OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 25 m, 0.25mm ID, USP: G3
1151G03726742.30OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 30 m, 0.25mm ID, USP: G3
1151G04726742.50OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 50 m, 0.25mm ID, USP: G3
1151G05726742.60OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 60 m, 0.25mm ID, USP: G3
1151B89726022.15OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 15 m, 0.25mm ID, USP: G3
1151B90726022.25OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 25 m, 0.25mm ID, USP: G3
1151B91726022.30OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 30 m, 0.25mm ID, USP: G3
1151B92726022.50OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 50 m, 0.25mm ID, USP: G3
1151B93726022.60OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 60 m, 0.25mm ID, USP: G3
1151C27726067.25OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 25 m, 0.25mm ID, USP: G3
1151C28726067.30OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 30 m, 0.25mm ID, USP: G3
1151C29726067.50OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 50 m, 0.25mm ID, USP: G3
1151C30726067.60OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 60 m, 0.25mm ID, USP: G3
1151G14726755.30OPTIMA® 17 capillary columns for GC, film thickness: 0.15 µm, length: 30 m, 0.32mm ID, USP: G3
1151D89726351.25OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 25 m, 0.32mm ID, USP: G3
1151D90726351.30OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 30 m, 0.32mm ID, USP: G3
1151D91726351.50OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 50 m, 0.32mm ID, USP: G3
1151D92726351.60OPTIMA® 17 capillary columns for GC, film thickness: 0.25 µm, length: 60 m, 0.32mm ID, USP: G3
1151G15726757.25OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 25 m, 0.32mm ID, USP: G3
1151G16726757.30OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 30 m, 0.32mm ID, USP: G3
1151G17726757.50OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 50 m, 0.32mm ID, USP: G3
1151G18726757.60OPTIMA® 17 capillary columns for GC, film thickness: 0.35 µm, length: 60 m, 0.32mm ID, USP: G3
1151G06726744.25OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 25 m, 0.32mm ID, USP: G3
1151G07726744.30OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 30 m, 0.32mm ID, USP: G3
1151G08726744.50OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 50 m, 0.32mm ID, USP: G3
1151G09726744.60OPTIMA® 17 capillary columns for GC, film thickness: 0.5 µm, length: 60 m, 0.32mm ID, USP: G3
1151G10726747.10OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 10 m, 0.53mm ID, USP: G3
1151G11726747.15OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 15 m, 0.53mm ID, USP: G3
1151G12726747.25OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 25 m, 0.53mm ID, USP: G3
1151G13726747.30OPTIMA® 17 capillary columns for GC, film thickness: 1 µm, length: 30 m, 0.53mm ID, USP: G3

Request penawaran harga & konsultasi produk?

Silakan isi form ini dan kami akan segera membalas ke kontak Anda!

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.