pH, Free Chlorine, and Total Chlorine Portable Photometer

SKU : 86b33ee2e667

Just a heads up! This Hanna Instruments product is no longer available. Don’t worry though, we’re still here to support you.

Quick question or technical issues? We can help.
Our Tech Team is just a phone call or email away. Please call us at800-426-6287or email us attech@hannainst.comdirectly for assistance. Our hours of operation are8:30am – 5:00pm EST.

Looking for a similar product?Check out our newestversionhere!

The HI96710 pH, Free Chlorine, and Total Chlorine Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the pH, free chlorine, and total chlorine concentration of water samples using ready made reagents. The HI96710 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter.

  • CAL Check™ Validation and Calibration
  • Built-in Timer
  • Automatic Shut Off

*Products classified as Dangerous Goods can only be shipped via ground.

Info penawaran harga dan pemesanan hubungi:

SKU 86b33ee2e667 Kategori :

The HI96710 portable photometer is for the measurement of pH, free chlorine, and total chlorine. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Check™ – Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.

GLP – Records the date of the last user calibration performed.

Built in timer – Ensures the appropriate reaction time is used for the chemical reaction. At the end of the timer the meter will automatically take the reading. This feature ensures consistency across multiple users.

Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.

Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.

Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.

Battery status indicator

The instrument has a battery level indicator to display remaining life as follows:

  • 3 lines for 100 % capacity
  • 2 lines for 66 % capacity
  • 1 line for 33 % capacity
  • Battery icon blinks when the capacity is less than 10 %.

Units of measure – Appropriate unit of measure is displayed along with reading.

optsystem_scritte-b

Three critical parameters that can be tested to ensure good water quality are pH, free chlorine, and total chlorine. Chlorine is one of the most commonly used disinfectants for drinking water, wastewater, and water used for pools and spas. It can be added to in various forms including calcium hypochlorite, sodium hypochlorite, or in some instances, chlorine gas. When added to water, chlorine creates hypochlorous acid (HOCl) which dissociates into hypochlorite ion (OCl).

HOCl ? H+ OCl

hypochlorous acid ? hydrogen ion + hypochlorite ion

HOCl is the form of chlorine that acts as a stronger disinfectant as compared to OCl. To ensure the added chlorine is effective at sanitizing, the pH of the water must be taken into account. Around pH 7.5, HOCl and OCl are present in relatively equal amounts. Below pH 7.5, the equilibrium shifts to favor HOCl; above pH 7.5, the equilibrium shifts to favor OCl. Depending on the application, addition of chlorine is effective when added to water with a neutral or slightly acidic pH value.

When chlorine is first added to water, it is available as free chlorine. The measurement of free chlorine signifies the amount available for disinfection. Once chlorine begins to sanitize bacteria and pathogens present in the water, it becomes combined chlorine; combined chlorine is no longer available to act as a disinfectant. The measurement of total chlorine signifies the amount of free chlorine and combined chlorine. With both free and total chlorine measurements, a drinking water operator or pool owner can determine if there is enough chlorine available for disinfection.

The HI96710 offers multiple methods within one meter. pH determination uses the phenol red method while free and total chlorine determination uses an adaptation of the EPA method 330.5 and Standard Method 4500-Cl G. The reagents are in powder and liquid form depending on the parameter being tested.

When the appropriate reagent is added to the sample, it will display a color change; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For determination of pH and free and total chlorine, a narrow band interference filter at 525 nm (green) allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

case-hi96700c

The HI96710 is available as a kit (HI96710C) which includes:

  • Portable Photometer
  • Sample cuvettes (2)
  • Caps
  • CAL Check™ standards with certificate
  • Cuvette cleaning cloth
  • Scissors
  • Rugged carrying case
  • Carrying case has thermoformed insert for meter and accessories

*Reagents ordered separately

Cal-Chck-yellow-1

CAL Check™ standards with certificate

The CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ function. Individual sets of CAL Check™standards are available for each parameter found in the HI96710:

  • pH: HI96710-11
  • Free Chlorine: HI96701-11
  • Total Chlorine: HI96711-11

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage

HI96-series-steps

 

 

 

Specification NameDetail
skuHI96710
Chlorine, Free & Total Range0.00 to 5.00 mg/L (ppm)
Chlorine, Free & Total Resolution0.01 mg/L under 3.50 mg/L; 0.10 mg/L over 3.50 mg/L
Chlorine, Free & Total Accuracy±0.03 mg/L ±3% of reading
Chlorine, Free & Total Methodadaptation of the USEPA method and Standard Method 4500-Cl G
pH Range6.5 to 8.5 pH
pH Resolution0.1 pH
pH Accuracy±0.1 pH
pH MethodPhenol Red method
Light Sourcetungsten lamp
Light Detectorsilicon photocell
Power Supply9V battery
Auto-offafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Weight320g (11.3 oz.)
Warranty 2 years

Isi data di bawah ini supaya kami bisa menghubungi Anda dengan harga penawaran terbaik.

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.