PRP-X400 Cation Exchange HPLC Columns

SKU : 5fdfb8d107a9

Info penawaran harga dan pemesanan hubungi:

SKU 5fdfb8d107a9 Kategori :

Polymeric cation exchange packing for separation of glyphosate and its metabolite in drinking water.

  • Faster analysis when compared to competitor’s columns
  • Detection levels of less than 10 ppb when using the post column, OPA derivatization technique
  • Applicable to other separations, such as inositol and sugar alcohols
  • pH stable from 1 to 13
     
  • Two particle sizes: 7 and 12-20 μm
  • Five column internal diameters: 2.1 to 21.5 mm
  • Two column materials: 316 stainless steel and PEEK
  • Analytical and semiprep/preparative guard columns

The PRP-X400 column provides a fast separation for glyphosate and its metabolites. The exchange capacity of the PRP-X400 is greater than that of the PRP-X200, leading to characteristics better suited for the separation of glyphosate. It also performs well in other separations, such as inositol and sugar alcohols. The column does not have to be heated to 65°C and operates well at room temperature, so a column heater is not necessary for this method. PRP-X400 columns do not require the use of methanol in the mobile phase, and they cost much less than other glyphosate columns.

Pack Your Own Columns – Hamilton offers a range of bulk polymer resins for customers who prefer to pack their own column hardware. Chromatographic capacity and efficiency tests are conducted on both bulk and packed column resins to ensure product integrity. Samples from different lots can be purchased for method and process validation.

Protect Your Investment – Hamilton guard columns protect analytical, semi-prep and preparative HPLC columns. They also remove particulate contaminants and highly adsorptive compounds from samples, prolonging column life. The designs are modular and cartridge replacement is easy and tool-free.  Cartridge holders for analytical columns are available in stainless steel and PEEK materials. Semi-prep/preparative holders are available only in stainless steel. The design of the cartridge holders is optimized to reduce dead volume and prevent extra column band broadening. Cartridge holders are reusable indefinitely.

PRP-X400 Cation Exchange
HPLC Columns, PRP-X400
Thomas No. 1216M16
Column, 7µm 250 x 4.1mm
Stationary Phase PRP-X400
Mode Cation Exchange
Packing Material Type PSDVB/Sulfonic Acid
Particle Size 7 µm
Pore Size N/A
Format Column
Hardware Inner Diameter 4.1 mm
Hardware Length 250 mm
Hardware Material Stainless Steel
Max. Pressure 5000
Exchange Capacity 2.5 meq/gm
Mobile Phase Limits pH 1-13. 0-100% aqueous, organic modifier
Buffer Strength 0.0-0.5N
Temp Limits 5-60°C
Restoration Inject several times with 100 µL of 0.1 M potassium EDTA
Compound Classification Glyphosate
UOM 1 Each
Exchange Capacity/Column 4.0 meq/column
Analytical Guard Column
Starter Kits and Cartridge
Replacements, PRP-X400
Thomas No. 0470U55
Column Starter Kit C-18
Thomas No. 0470U59
Cartridge Replacement C-18 Pk5
Stationary Phase HxSil C18 HxSil C18
Mode Reversed-Phase Reversed-Phase
Packing Material Type Silica Silica
Particle Size 10 µm 10 µm
Format Guard Cartridge Kit Replacement Guard Cartridge
Hardware Inner Diameter 2.1 mm 2.1 mm
Hardware Length 20 mm 20 mm
Guard Column Size Analytical
Hardware Material Stainless Steel Stainless Steel
Max. Pressure 5,000 psi 5,000 psi
Mobile Phase Limits pH 2.0 – 7.5 pH 2.0 – 7.5
Compound Classification General Purpose General Purpose
UOM 1 holder, 2 cartridges 5/p
Analytical Guard Column
Starter Kits and Cartridge
Replacements, PRP-X400
Thomas No. 1177F72
Analytical Guard Column Starter Kit
Thomas No. 1177FF83
Analytical Guard Column
Stationary Phase PRP-X400 PRP-X400
Mode Cation Exchange Cation Exchange
Packing Material Type PSDVB/Sulfonic Acid PSDVB/Sulfonic Acid
Particle Size 7 µm 7 µm
Format Guard Cartridge Kit Guard Column
Hardware Inner Diameter 2.1 mm 2.1 mm
Hardware Length 20 mm 33 mm
Guard Column Size Semiprep/Preparative Analytical
Hardware Material Stainless Steel Stainless Steel
Max. Pressure 5,000 psi 5,000 psi
Mobile Phase Limits pH 1-13. 0-100% aqueous, organic modifier _
Compound Classification Organic/Inorganic Cations Glyphosate
UOM 1 holder, 2 cartridges 1 Each
Bulk Resin, PRP-X400 Thomas No. 1177F84
7 µm Bulk Resin
Thomas No. 1177F845
12-20 µm Bulk Resin
Thomas No. 1177F86
30-50 µm Bulk Resin
Stationary Phase PRP-X400 PRP-X400 PRP-X400
Mode Cation Exchange Cation Exchange Cation Exchange
Particle Size 7 µm 12-20 µm 12-20 µm
Pore Size N/A N/A N/A
Format Bulk Resin Bulk Resin Bulk Resin
Max. Pressure 5,000 psi 5,000 psi 5,000 psi
Exchange Capacity 2.5 meq/gm 2.5 meq/gm 2.5 meq/gm
Restoration Inject several times with 100 µL of 0.1 M potassium EDTA Inject several times with 100 µL of 0.1 M potassium EDTA Inject several times with 100 µL of 0.1 M potassium EDTA
UOM per gram per gram per gram
Thomas No Mfr No Description
0470U55 79459 Column Starter Kit C-18
0470U59 79452 Cartridge Replacement C-18 Pk5
1216M16 79473 Column, PRP-X400 7µm 250 x 4.1mm
1177F84 79591 PRP-X400, 7 µm Bulk Resin
1177F85 79592 PRP-X400, 12-20 µm Bulk Resin
1177F86 79593 PRP-X400, 30-50 µm Bulk Resin
1177F72 79224 PRP-X400 Analytical Guard Column Starter Kit (1 holder, 2 cartridges), Stainless Steel
1177F83 79290 Analytical Guard Column, PRP-X400

Request penawaran harga & konsultasi produk?

Silakan isi form ini dan kami akan segera membalas ke kontak Anda!

Isi form di bawah ini dengan lengkap dan benar. Kami akan segera menghubungi Anda dengan penawaran harga terbaik. Terima kasih.